Construction phase - BC-ETS 01
In this section, you can find more details and videos of each pile of the BC Experimental Testing Site 01.

EC1
​
Lenght: 25 m
Diameter: 60 cm
Instrumentation: Strain gauges (5 levels)
Characteristics: 25 m of continuous auger penetration; Static compression test

EC2
​
Lenght: 25 m
Diameter: 60 cm
Instrumentation: Strain gauges (5 levels)
Characteristics: 25 m of continuous auger penetration; Static compression test

ECP5
​
Lenght: 25 m
Diameter: 60 cm
Instrumentation: Strain gauges (5 levels)
Characteristics: 10 m with extension rod + 15 m with continuous auger; Static compression test

ECP6
​
Lenght: 25 m
Diameter: 60 cm
Instrumentation: Strain gauges (5 levels)
Characteristics: 10 m with extension rod + 15 m with continuous auger; Static compression test

ET1
​
Lenght: 25 m
Diameter: 60 cm
Instrumentation: Strain gauges (5 levels)
Characteristics: 25 m of continuous auger penetration; Static tension test

ET2
​
Lenght: 25 m
Diameter: 60 cm
Instrumentation: Strain gauges (5 levels)
Characteristics: 25 m of continuous auger penetration; Static tension test

ED1
​
Lenght: 25 m
Diameter: 60 cm
Instrumentation: Strain gauges (5 levels)
Characteristics: 25 m of continuous auger penetration;
Dynamic load tests (PDA with stepwise energy)

ED2
​
Lenght: 25 m
Diameter: 60 cm
Instrumentation: Strain gauges (5 levels)
Characteristics: 25 m of continuous auger penetration;
Dynamic load tests (PDA with stepwise energy)

EC3
​
Lenght: 41,60 m
Diameter: 60 cm
Instrumentation: Strain gauges (7 levels)
Characteristics: Reinforced with full-length steel
H-section; Static compression test;
Partially socketed in fractured rock

EC4
​
Lenght: 38,58 m
Diameter: 60 cm
Instrumentation: Strain gauges (7 levels)
Characteristics: Reinforced with full-length steel
H-section; Static compression test;
Partially socketed in fractured rock