Construction phase - BC-ETS 01

In this section, you can find more details and videos of each pile of the BC Experimental Testing Site 01.

EC1

​

Lenght: 25 m

Diameter: 60 cm

Instrumentation: Strain gauges (5 levels)

Characteristics: 25 m of continuous auger penetration; Static compression test

EC2

​

Lenght: 25 m

Diameter: 60 cm

Instrumentation: Strain gauges (5 levels)

Characteristics: 25 m of continuous auger penetration; Static compression test

ECP5

​

Lenght: 25 m

Diameter: 60 cm

Instrumentation: Strain gauges (5 levels)

Characteristics: 10 m with extension rod + 15 m with continuous auger; Static compression test

ECP6

​

Lenght: 25 m

Diameter: 60 cm

Instrumentation: Strain gauges (5 levels)

Characteristics: 10 m with extension rod + 15 m with continuous auger; Static compression test

ET1

​

Lenght: 25 m

Diameter: 60 cm

Instrumentation: Strain gauges (5 levels)

Characteristics:  25 m of continuous auger penetration; Static tension test

ET2

​

Lenght: 25 m

Diameter: 60 cm

Instrumentation: Strain gauges (5 levels)

Characteristics:  25 m of continuous auger penetration; Static tension test

ED1

​

Lenght: 25 m

Diameter: 60 cm

Instrumentation: Strain gauges (5 levels)

Characteristics: 25 m of continuous auger penetration;

Dynamic load tests (PDA with stepwise energy)

ED2

​

Lenght: 25 m

Diameter: 60 cm

Instrumentation: Strain gauges (5 levels)

Characteristics: 25 m of continuous auger penetration;

Dynamic load tests (PDA with stepwise energy)

EC3

​

Lenght: 41,60 m

Diameter: 60 cm

Instrumentation: Strain gauges (7 levels)

Characteristics: Reinforced with full-length steel

H-section; Static compression test;

Partially socketed in fractured rock

EC4

​

Lenght: 38,58 m

Diameter: 60 cm

Instrumentation: Strain gauges (7 levels)

Characteristics: Reinforced with full-length steel

H-section; Static compression test;

Partially socketed in fractured rock